  1. Question 1 · A/C Diagnosis & Service

    With the A/C on and the compressor clutch engaged, the high and low side pressures are almost equal. What is the most likely cause?

    1. The compressor is not pumping
    2. The system is overcharged
    3. The orifice tube is restricted
    4. The condenser fan is not working
    Show answer and explanation

    Answer: A. The compressor is not pumping

    The compressor creates the pressure difference. If the clutch is engaged and pressures stay equal, it is not compressing, from internal failure or a failed variable displacement control valve.

  2. Question 2 · A/C Diagnosis & Service

    Both high and low side pressures are high and vent air is warm. The condenser fan does not run. What is the cause?

    1. A low refrigerant charge
    2. A restricted orifice tube
    3. A slipping compressor clutch plate
    4. Poor airflow across the condenser
    Show answer and explanation

    Answer: D. Poor airflow across the condenser

    The condenser must reject heat. Without airflow, heat stays in the refrigerant, raising both pressures and reducing cooling. Fix the fan before adjusting the charge.

  3. Question 3 · Refrigeration Components

    After running for several minutes, the low side gauge reads vacuum and the high side reads low. What is the most likely cause?

    1. Air and moisture mixed into the refrigerant
    2. An overcharged system flooding the evaporator
    3. A restriction at the TXV or orifice tube, often from ice
    4. A failed compressor with a broken reed valve
    Show answer and explanation

    Answer: C. A restriction at the TXV or orifice tube, often from ice

    A restriction starves the low side, pulling it into vacuum and lowering high side pressure. Moisture can freeze at the metering device and act as a restriction. Fix: replace the metering device and desiccant, then evacuate thoroughly.

  4. Question 4 · Refrigerant Handling

    An A/C system is being opened for repair.

    Technician A says the refrigerant must be recovered with approved equipment before opening the system.

    Technician B says R-134a and R-1234yf use the same service port fittings.

    Who is correct?

    1. A only
    2. B only
    3. Both A and B
    4. Neither A nor B
    Show answer and explanation

    Answer: A. A only

    Technician A is right: venting refrigerant is illegal under federal rules. Technician B is wrong: R-1234yf uses different service fittings to prevent cross-contamination, and each refrigerant needs its own equipment.

  5. Question 5 · Heating & Engine Cooling

    The heater blows warm air at highway speed but cool air at idle. What is the most likely cause?

    1. Low coolant or air trapped in the cooling system
    2. A blend door stuck in the cold position
    3. A failed blower motor resistor
    4. A thermostat that is stuck closed
    Show answer and explanation

    Answer: A. Low coolant or air trapped in the cooling system

    At idle, the water pump moves less coolant, so a low level or air pocket cannot keep the heater core full. At higher RPM, flow improves. Check level, look for leaks, and bleed the system as specified.

  6. Question 6 · Controls

    The blower motor runs only on high speed. What is the most likely cause?

    1. A blower motor with worn brushes
    2. A blown fuse in the blower circuit
    3. A faulty A/C high pressure switch
    4. An open blower resistor or failed blower module
    Show answer and explanation

    Answer: D. An open blower resistor or failed blower module

    On many systems, high speed bypasses the resistor and sends full voltage to the motor. The lower speeds go through the resistor, so an open resistor kills them. A failed motor or fuse would stop all speeds.

  7. Question 7 · Heating & Engine Cooling

    Poor heater output could be caused by all of the following EXCEPT:

    1. A restricted heater core
    2. A misadjusted blend door cable
    3. A thermostat stuck closed
    4. A thermostat stuck open
    Show answer and explanation

    Answer: C. A thermostat stuck closed

    A thermostat stuck closed makes the engine run hot, and the heater usually still gets hot coolant. A stuck-open thermostat keeps the engine too cool for good heat. A restricted core or wrong blend door position also cut heat.

  8. Question 8 · Refrigeration Components

    What is the job of the condenser?

    1. To meter refrigerant into the evaporator
    2. To absorb heat from the cabin air
    3. To remove heat from hot vapor and turn it to liquid
    4. To store extra refrigerant for high loads
    Show answer and explanation

    Answer: C. To remove heat from hot vapor and turn it to liquid

    The condenser is in front of the radiator. Hot, high-pressure vapor gives off heat to outside air and condenses into a liquid.

  9. Question 9 · Controls

    A/C air comes out of the defrost vents only, no matter which mode is selected. On a vacuum-controlled system, what is a likely cause?

    1. A blown fuse in the A/C circuit
    2. A low refrigerant charge in the A/C system
    3. A vacuum leak or loose vacuum supply line
    4. A failed blower motor on low speed
    Show answer and explanation

    Answer: C. A vacuum leak or loose vacuum supply line

    Many vacuum systems default to defrost when vacuum is lost, for safety. Check the vacuum supply, reservoir and check valve.

  10. Question 10 · Refrigerant Handling

    Under EPA rules, technicians who service motor vehicle A/C for money must be:

    1. Certified under Section 608 only
    2. ASE Master certified in automotive
    3. Licensed by the state as electricians
    4. Section 609 certified, using approved equipment
    Show answer and explanation

    Answer: D. Section 609 certified, using approved equipment

    Section 609 of the Clean Air Act covers motor vehicle A/C. Section 608 covers stationary systems. Equipment must meet the SAE standard for the refrigerant being handled.

Keep practicing A7 Unlock all 50

How to answer A7 questions

Frequently asked questions

How many questions are on the ASE A7 Heating & Air Conditioning test?

50 scored multiple-choice questions. ASE may add a few unscored research questions that do not count toward your score.

How long is the ASE A7 Heating & Air Conditioning test?

1 h 15 min. That is about 1.5 minutes per question.

What is on the ASE A7 Heating & Air Conditioning test?

The task areas are: A/C Diagnosis & Service; Refrigeration Components; Heating & Engine Cooling; Controls; Refrigerant Handling.

How many ASE A7 Heating & Air Conditioning practice questions does BayReady have?

50 ASE-style practice questions with explanations, including 6 Technician A / Technician B questions. 10 are free, and BayReady Pro unlocks the rest plus unlimited timed mock exams.

Does A7 count toward Master Technician?

A1–A8 together earn Automobile & Light Truck Master Technician status, along with the required work experience.

Other Automobile & Light Truck tests